DAIKIN FDYQN180LC-M2Y 18.0kW Inverter Ducted Air Conditioner System 3 Phase

$6,251.00

18.0 kW Cooling | 20.0 kW Heating
DAIKIN FDYQN180LC-M2Y 18.0kW Inverter Ducted Air Conditioner System | 3 Phase | R410A
Includes Indoor – FDYQN180LCV1 | Outdoor – RZQ180M2Y1
Available Controllers:
Included:
BRC1E63  – Standard Nav Ease Controller
Optional:
BRC230Z4B9 – Up to 4 Zones (230-240v)
BRC230Z8B9 – Up to 8 Zones (230-240v)
BRC24Z4B9   – Up to 4 Zones (24v)
BRC24Z8B9   – Up to 8 Zones (24v)

Category:

Description

INDOOR UNIT FDYQN180LCV1
OUTDOOR UNIT RZQ180MY1
Rated Capacity Cool (kW) 18.0
Heat (kW) 20.0
Capacity Range Cool (kW) 9.0-18.0
Heat (kW) 10.0-20.0
Power Input (Rated) Cool (kW) 5.82
Heat (kW) 6.11
E.E.R/C.O.P C/H 3.09/3.27
TCSPF (Residential) Hot/Average/ Cold 3.61/3.15/3.13
HSPF (Residential) Hot/Average/ Cold 3.23/2.95/2.61
Airflow Rate  (Nominal/Max) l/s 1160/1200
Indoor Sound Level (H) @ 1.5m dBA (C/H) 45.0/45.0
Piping Length m 50
Indoor Fan Speeds H/M/L
Dimensions (HxWxD) Indoor (mm) 470x1200x997
Outdoor (mm) 1430x940x320
Weight Indoor (kg) 70
Outdoor (kg) 138
Power Supply V/Hz 3 Phase, 380-415V, 50Hz
Compressor Type Hermetically Sealed Scroll Type
Refrigerant R410A
Pipe Sizes Liquid (mm) 9.5 (Brazed)
Gas (mm) 19.1 (Brazed)
Drain (mm) BSP 3/4 inch Internal Thread
Supply Air Opening mm (HxW, Flange) 350×918
Return Air Opening mm 393×918 (Flange)
Outdoor Operating Range Cool (°CDB) -5 to 43
Heat (°CWB) -20 to 16
EPA Sound Power Level dBA 72
Outdoor Sound Level (H) @ 1m Pressure dBA (C/H) 57/58